18. Common Reference System
18-4
You can set access server display options ON if you want to monitor access server windows to know harmonization
status, whenever harmonization is completed by the system.
Function keys
Operation
X
Parameter backup
Digitizer
Backup and Restore
Installation parameters
Navigation parameters
X
Chart Alert parameters
Optimization parameters
X
Print Navigation parameters
X
Print Optimization parameters
X
Selftest
Standby
Presentation Library
Access Server and Diagnostic
X
Close
To set access server display ON/OFF, do the following:
1. Spin the scrollwheel to display Menu/Info/Chart Menu in the
mouse functions area then push the left mouse button.
2. Select Initial Settings then push the scrollwheel.
3. Put the cursor on the triangle in the Initial Settings dialog box
to show the menu shown left.
4. Select Access Server and Diagnostic from the menu then
Access Server Display from the submenu.
When access server windows are displayed, the messages shown
below may appear.
If the system recognises that any data
mentioned above has been changed in one
workstation, the access server indicates the
need for pending harmonisation, using the
window shown right.
When the access server recognises that the
editing, loading, updating, etc. session has
been completed in one workstation, the access
server starts harmonising databases in order to
get databases identical on all workstations.
The message "Access Server is currently
harmonizing" appears to alert you to this
action. If you click the Show Details…
button, the "Progress of harmonization"
window appears to give detailed information
about harmonization progress. This window
can be closed by clicking the Close Details
button on the "Access server is currently
harmonizing" window.
Note: The Stop button in the Progress of
harmonization window stops the
harmonization in case of system malfunction.
When route, user chart or Notes is selected for the planning mode, the access server locks it and rejects further
selection of it in other workstations until "Enable changes" selection is removed or the Plan Route dialog box is
closed.
Harmonising starts when "Enable changes" selection is unchecked or corresponding window(s) are closed. After
harmonisation has been done, the route, user chart or Notes can be selected in another workstation for the planning
mode.