FURUNO
FEA-2107/2807 Series
E4122S02E
SP-3
Optional interface
- Gyrocompass: analog signal (synchro or step)
- Speed log: analog signal (200 p/m)
- Navigational echosounder: serial data (IEC 61162-1 DBT)
- Wind indicator: serial data (IEC 61162-1 MWV)
- Position sensor: serial data
- 2 lines of alarm output, alarm output selection
15. Power Supply
Display unit
MU-190: 100-230 VAC, single phase, 50-60 Hz, 0.7-0.4A
MU201CE: 100-230 VAC, single phase, 50-60 Hz, 0.6-0.4A
MU-231/MU231CE: 100-230 VAC, single phase, 50-60 Hz, 0.6-0.4A
Processor unit, control unit 100-230 VAC, single phase, 50-60 Hz, 1.5-0.5A
LAN adapter 24 VDC, 0.15 A
B adapter 24 VDC, 0.20 A
16. Environmental Conditions
Useable temperature Control unit/processor unit/display unit: -15°C to +55°C
Relative humidity 93% ±3% (+40°C)
Vibration - From 2 Hz-5 Hz to up to 13.2 Hz: ±1 mm ±10%
- 13.2Hz-100Hz: max velocity 7 m/s
2
Waterproofing Display unit: IXPS
Processor unit: IPX0
Other units: IPX0
17. Color Display unit: N3.0 Newton No. 5
Chassis: 2.5GY5/1.5
Processor unit: 2.5GY5