1. MOUNTING THE UNIT
5
For 50 or 100 m cable
1. Apply silicone sealant (local supply) to the threads of the pipe.
2. Unscrew three screws to remove the antenna base from the antenna unit.
3. Pass the cable assy TPA5FB0.3NJ5FBA-5DFB (supplied, 300 mm) into the shrink tube
(SCM2, supplied).
4. Attach the above cable assy to the connector at the bottom of the antenna unit (upper).
5. Shift up the shrink tube until it touches the bottom of the antenna unit (upper).
6. Heat the shrink tube, and then apply silicone sealant to the upper edge of the tube, also
wind self-bonding tape around the lower edge of the shrink tube and then wrap vinyl
tape over self-bonding tape.
Note: Between the bottom of the antenna unit (upper) and the end of the taping should be
less than 50 mm.
7. Insert the cable protector (supplied) in to the slot at the bottom of the antenna base.
8. Pass the antenna cable through the pipe and antenna base in order.
When laying the cable along side the pipe, put the cable aside to pass through the projection
in the antenna base. See [A] in the figure shown below.
Waterproofing
9. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%)
10. Screw the antenna unit onto the antenna pipe by rotating the antenna unit.
11. Wind self-bonding tape (supplied) at the connection of antenna base and pipe, and then
wrap vinyl tape over self-bonding tape.
12. Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna
unit and the ground stud on the mast.