EasyManua.ls Logo

Furuno FM-8800D - Measurement; VHF Frequency

Furuno FM-8800D
268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2 Measurement
6-3
6.2 Measurement
6.2.1 VHF Frequency
As a reference oscillator for this equipment, TCXO (Temperature Compensated Crystal
Oscillators) is used. And there is no adjustment part of frequency.
Regulated range of frequency tolerance is within +10 ppm (+1.5 kHz approximately). If
the tolerance is more/less than +10 ppm, replace CPU board or Y1 (TCXO: 25.6 MHz)
on CPU board.
Connect the frequency counter as below. Read the frequency of the setup channel when
PTT switch is ON.
The frequency tolerance: within +10 ppm
Fig. 6.2.1 Frequency Measurement
or
50 ohm
Dummy
Antenna
FM-8800S
FM-8800D
ANT
CH70 ANT
50 ohm
Power meter
Handset
Freq. Counter
The input to a frequency counter approximates the pick-up coil to
a
dummy load or ANT coaxial cable and picks up TX frequency.

Table of Contents