1. INITIAL SETTINGS AND ADJUSTMENTS
1-21
2. Check the check box of [MCV001] to activate.
3. Click [Details] to display the window as shown below. For the descriptions of the
each items, see step 3 of section 1.4.2.
4. Click [No.1 Sensor Adapter] on the menu bar.
The sensor adapter consists of four sub units: [Serial Input/Output], [Digital In-
put]*, [Digital Output]*, and [Analog Input]*. [Analog Input] is not used on the FMD-
3100.
* Not displayed when the MC-3000S is connected directly to LAN. If it is necessary
to change the setting, connect the MC-3000S via the PCU-3010.
5. Click [Serial Input/Output]. There are eight ports in the Serial Input/Output. [Serial
01] to [Serial 04] can input/output at 38,400 bps for the AIS and Gyro.
The connector no. on the MC-3000S board and the corresponding serial port no.
are shown in the following table.
6. Set the items referring to step 6 of section 1.4.2.
Connector No. Serial Port No. Connector No. Serial Port No.
J4 Serial 01
J8
Serial 05
J5 Serial 02 Serial 06
J6 Serial 03
J9
Serial 07
J7 Serial 04 Serial 08