EasyManua.ls Logo

Furuno FMD-3100 - Page 30

Furuno FMD-3100
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. INITIAL SETTINGS AND ADJUSTMENTS
1-24
9. Click [Digital Output] on the menu bar.
[Channel 01-01] to [Channel 10-08] are shown on the display. Each sensor adapt-
er MC-3030D has eight input ports. When one sensor adapter MC-3030D is con-
nected to the MC-3000S, [Channel 01-01] to [Channel 01-08] can be used. When
ten sensor adapters MC-3030D are connected, [Channel 01-01] to [Channel 10-
08] can be used.
The connector no. on the MC-3030D board and the corresponding channel no.
are shown below.
No.1 sensor adapter MC-3030D
No.2 sensor adapter MC-3030D
10. Check the checkbox for [Channel No.] to set the items referring to the table shown
below.
Connector No. Channel No. Connector No. Channel No.
J3
Channel 01-01
J5
Channel 01-05
Channel 01-02 Channel 01-06
J4
Channel 01-03
J6
Channel 01-07
Channel 01-04 Channel 01-08
Connector No. Channel No. Connector No. Channel No.
J3
Channel 02-01
J5
Channel 02-05
Channel 02-02 Channel 02-06
J4
Channel 02-03
J6
Channel 02-07
Channel 02-04 Channel 02-08

Table of Contents