1. INITIAL SETTINGS AND ADJUSTMENTS
1-25
11. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
Item Remarks
[Data Cate-
gory]
Sets the data category. Settings: [ALERT], [ACK], [BUZZER STOP], [OP-
ERATOR FITNESS], [OTHER], [TRANSFER], [BACKUP NAVIGATOR].
Note: Do not select [OPERATOR FITNESS]. The FMD-3100 does not
support it.
[+] button This appears when the [Data Category] is set to [ALERT]. Click to show
the configuration of the alert output.
• [Equipment ID]: The Equipment ID is shown.
• [Alert ID]: The alert notification sentence* (ALF or ALR) and alert num-
ber are shown. When the alert notification sentence is ALF, the in-
stance ID is shown.
*: According to setting of [Output Data Type for INS] in the [AMS] menu
(see section 1.7).
• [ ] button: Opens the [Alert No. Setting] window to select the output
alert. The following example uses the alert notification sentence ALF.
Check the radio button of the desired alert and click the [OK] button.
• [Alert Name]: The alert name is shown.
[Equipment
ID]
Select the Equipment ID from the pull-down list.
The pull-down list options change according to the setting at [Sensor Set-
ting].
[Details] • [Name]: Enter the appropriate sensor
name.
• [Output Time (100msec)]: Set the out-
put time.
• [Dead Band (100msec)]: Set the dead
band after output.
• [Calibration Active]: Keep the default
setting. (Default: without check)
• [Active Status (1)], [Active Status (0)]:
Keep the default setting.
Example: ALF is the alert notification sentence.
MCV001 - Digital Output - Board01 Channel01