1. INITIAL SETTINGS AND ADJUSTMENTS
1-35
1.5.3 [CCRS Setting] window
Set if the NSR sentence is output from the CCRS in the [CCRS Setting] window of the
[TCS] menu. This setting is currently unavailable. Confirm that the box has no check
mark.
1.6 [TCS] Menu
This menu is not functional on the FMD-3100.
1.7 [AMS] Menu
The AMS menu sets up the interface between the AMS (Alert Management System)
and the FMD-3100, including the AMS operating mode.
Note: For how to set the alert definition of AMS, see the FURUNO information.
1.7.1 AMS mode operation
1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Operation Mode Setting] on the menu bar.
item Remarks
[Alert Monitoring In-
terval]
Set the time to wait before clearing the corresponding alert when
communication with a sensor is interrupted.
[Disable Alert Time-
out Clear] (01 to 05)
Select the units where the alert is not to be cleared.
[Output Data Type
For INS]
Select the data type of alert notification, ALR or ALF.
[Enable Category A
Buzzer]
Select if the alert buzzer sounds when the alert of Category A oc-
curs.
Remove the checkmark.