1. INITIAL SETTINGS AND ADJUSTMENTS
1-47
2. Set the options referring to the table shown below.
3. Click the [OK] button to close the [New Alert] window.
4. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
Item Remarks
[Alert Name] (ALR)
[Alert Description] (ALF)
Enter the alert name (max. 64 characters).
[Alert ID] (For ALF) Enter the alert number for the ALF sentence.
[Instance ID] (For ALF) Enter the Instance ID.
[Internal Notify No.] Enter the notify number of the equipment. For sensors, this
is automatically numbered.
[Input Unit] Select the input source for the alert.
For other than sensors: [Internal], [Digital]
For sensors: [CCRS], [Digital], [MODBUS]
[Is Active] Activate/Deactivate the alert. [YES]: activated, [NO]: deacti-
vated.
[Priority] The priority of the alert group ([Emergency]/[Alarm]/[Warn-
ing]/[Caution]).
[Category] The category of the alert group (A to C).
[Emergency Icon] Select the icon for the emergency alert. Available only for
alerts with [Priority] set to [Emergency].
[Emergency Buzzer] Select the buzzer sound for the emergency alert. Available
only for alerts with [Priority] set to [Emergency].
[Escalation Mode] Select the priority that escalates the status of an alert,
[Alarm] or [Warning]. Available only for alerts with [Priority]
set to [Warning].
[Alarm]: When the alert is left unacknowledged, the priority
is changed to [Alarm].
[Warning]: When the alert is left unacknowledged, the pri-
ority remains as [Warning]. Then, the alert buzzer sounds
again.
[Escalation Time] Set the time to wait before activating the escalation function
against an alert. Available only for alerts with [Priority] set to
[Warning].
[Escalation Transfer] Enable or disable transfer of an Alarm priority alert in the
transfer escalation mode. Available only for alerts with [Es-
calation Mode] set to [Alarm].
[Transfer Time] Set the time to wait before transferring an Alarm priority alert
in the transfer escalation mode. Available only for alerts with
[Escalation Mode] set to [Alarm].
[Integrated Alert] Keep the default setting.
[Send VDR] Select [YES] to transfer the ALR sentence to the VDR.
[Clear Non-Ack Alert
when Rectified]
Select [YES] to delete the non-acknowledged alerts auto-
matically when they are rectified.
[Detailed Information] Enter the detail information (max. 1023 characters) of the
alert.