One compact communication unit allows us to use full Inmarsat B services: telephone,
fax, telex, 9.6k data (MSD), and HSD communications. The FELCOM 82 works from
AC power supply, 110 VAC or 220 VAC. There are two models of FELCOM 82:
FELCOM 82A (class 1) and FELCOM 82B (class 2). The FELCOM 82A consists of an
antenna unit, a communication unit, a handset, a junction box, a printer, a telex terminal
unit, and distress alert buttons. The FELCOM 82B does not have a telex terminal unit.
The optional multi-communication unit increases the number of telephone and/or
facsimile machine that may be connected from 3 sets to 10 sets. A telephone, a
facsimile machine, a multi communication unit (PBX), an incoming indicator, and a
credit card call adapter are also supplied optionally. The telephone distress alert button
may be located at either the IB-362, or at the handset hanger, which utilizes a built in
distress alert button. The system requi
Section H3. FELCOM 82
Handset &
Hanset hanger
IB-882
IB-882/362(Tel DIS)
Junction
box
IB-313
No.1 Tel
or FAX
MJ-2S
MJ-2S
Tel
or FAX
No.3-1
MJ-2S
No.2 Tel
or FAX
MJ-2S
No.3 Tel
or FAX
MJ-2S
Incoming
Indicator
IB-372
TLX DIS
ALT Button
IB-352
TEL DIS
Button
IB-362
NAV
Multi communication unit
Tel or FAX
No.3-2
MJ-2S
Tel or FAX
No.3-3
MJ-2S
Tel or FAX
No.3-4
MJ-2S
Tel or FAX
No.3-5
MJ-2S
Tel or FAX
No.3-6
MJ-2S
Tel or FAX
No.3-7
MJ-2S
Tel or FAX
No.3-8
MJ-2S
Tel or FAX
100/220VAC
100/220VAC
100/220VAC
Credit call adapter
& Card Reader
ANT
HANDSET
JUNCTION
Antenna unit
IB-182
Gyro
Gyro
Terminal unit
IB-582
Printer
PP-510
Keyboard
Class-1
Class-2
VDU
PRINTER
24V
24V
PC
(For MSD)
PC
(For HSD)
HSD I/F
MSD
HSD
(9.6k data)
(56/64k)
EX) KlasHpopper
PCMCIA-400/PCI-400
8D-FB-CV:30/50m
12D-SFA-CV:100m
IB-282
Communication
unit
AC IN
AC IN
To TEL3 port
IB-782
IB-781
Can not be used
when IB-882/362 is used.

Table of Contents