1. HOW TO INSTALL THE SYSTEM
1-5
1.2.3 Installation procedure
Outdoor installation
Fasten the Antenna Coupler to a bulkhead of the bridge, mast, handrail, etc., with the
M6 bolts (local supply).
For installation on the mast, see section 1.5 to select a location. Weld suitable mount-
ing fixtures (local supply) to the mast and bolt the coupler there.
Indoor installation
Fasten the Antenna Coupler to a bulkhead on the bridge or the overhead. Select a lo-
cation where the distance between the lead-in insulator and the coupler is as short as
possible.
DO NOT install
coupler horizontally.
Fix with four
M6 bolts
(local supply).
Mounting fixture
(Local supply)
Pictured: AT-5075
UP
Air vent
Make sure it is not blocked.
From automatic antenna switch AS-102
Stand-off
insulator
Lead-in
insulator
Automatic antenna switch AS-102
Installation on a bulkhead
Installation on the overhead