3. INITIAL SETTINGS
3-9
Full duplex configuration 2: R_ANT and WR2 antennas commonly shared
1) Set [RX ANT] on the [RT SETUP] menu to [CONNECT].
2) Set [ANT SELECT] on the [RT SETUP] menu to [RX ANT].
3) Turn on [DIVIDER] in the [RT SETUP] menu of the [SERVICE] menu.
3.5 Alarm Contact Signal
Set the format of the alarm contact signal for normal close or normal open, with the
jumper block J8 on the T-IF Board (05P0861).
R_ANT T/R_ANT
T/R_ANT
J8
R_ANT
WR1_ANT
J7
J6
J5
J4
J3
J1
J2
J3
J3
J1
J2
J2
J2
J2
WR1_ANT
Jumper block J8
Normal
close
Normal
open