8. Power and Frequency measurement of
MF/HF Radiotelephone
MF/HF DSC signal is not transmitted by pressing a PTT switch, because of its emission
mode of F1B (J2B). Tone signals (1700Hz +
85Hz) must be input to the radiotelephone.
To measure the output power of DSC signal, follow the below.
The radiotelephone must be set to the frequency to measured and to F1B (J2B/TLX).
1. Pressing [#/SETUP] key reveals Setup menu screen. Select TEST and press [ENT]
key. Then, the following Test function screen appears.
To execute the test function, cancel PROTECTION. Enter 652111 from the
numeric keys.
2. Selecting TONE and pressing [ENT] key reveals a submenu.
Choose MARK or SPACE on the submenu, and turn the signal ON by pressing
[ENT] key. For example, choose MARK”.
3. Transmit power by turn ON the handset PTT switch of DSC-60, and measure the
frequency and power.
4. To measure other frequencies, turn OFF the handset PTT switch and change the
frequency of MF/HF radiotelephone. Repeat steps 3 and 4.
5. After the completion of the measurements, turn off power for DSC-60.
* * Test function * *
TONE
BK
REMOTE
EXT ALARM
EXT ALERT
AF PCB
CONT PCB
PANEL PCB
RX PCB
TA TEST
PROTECTION : ON
* * Setup menu * *
ALARM
AUTO ACK
ERASE FILE
MESSAGE
POSITION
SCAN FREQ
USER CH
VOLUME
TEST
SYSTEM
PRINT OUT
[ENT]
* * Test function * *
TONE
BK
REMOTE
EXT ALARM
EXT ALERT
AF PCB
CONT PCB
PANEL PCB
RX PCB
TA TEST
PROTECTION : OFF
SPACE
:OFF
:OFF
:OFFDOT
MARK
MARK:1700Hz 85Hz
SPACE:1700Hz + 85Hz
DOT:1700Hz +
85Hz