2. WIRING
2-16
2.5 AC-DC Power Supply Unit PR-300/PR-850A (op-
tion)
To connect to both an AC and DC ship’s mains, the optional AC-DC power supply unit
PR-300 (FS-1575) or PR-850A (FS-2575/FS/5075) is required. Attach the crimp on
lug FV5.5-4 (local supply) to the following cables or equivalent (local supply) for con-
nection with the power supply unit.
AC power: DPYC-6
DC power: DPYC-6 (FS-1575), DPYC-10 (FS-2575), DPYC-16 (FS-5075)
How to process power cables
Fabricate the cable as shown below. Connect cables to their input terminals with
crimp-on lugs.
How to select input voltage
PR-300 for FS-1575:
The input voltage is adjustable for 100/110/200/220 VAC, and is factory-set for 220
VAC. To select other input voltages, open the top cover and change the wiring accord-
ing to the figure on the next page and change the power fuse accordingly to AC input
voltage as follows.
Input voltage Power fuse
100/110 VAC 10 A
200/220 VAC 5 A
6 mm
FV5.5-4 (Yellow)
Armor
Sheath
Vinyl tape
70
50
180 (FS-1575T)
150 (FS-2575T,
FS-5075T)
LED(red)
LED(green)
Fuse for AC ships main
AC power
source swith
AC-DC power supply unit PR-300, rear view
DC power
source swith