1. HOW TO INSTALL THE SYSTEM
1-5
Emergency switch
The emergency switch is attached to the port side of the hull unit. If the port side clear-
ance is not sufficient for switch operation, the switch may be remounted on the star-
board side.
Note: The junction box FSV-2550 cannot be mounted to the hull unit when the emer-
gency switch is remounted on the starboard side. Mount the junction box to a bulkhead
near the hull unit.
Hex nut
Hex bolt
Spring washer
Flat washer
Flat washer
O-ring
Fastening torque: 230 N•m
Fastening torque: 230 N•m
Hex nut
Spring
washer
Flat
washer
O-ring
Stern side
Hex nut
Hex bolt
Spring
washer
Flat
washer
O-ring
Retraction tank
(17 places)
Bow side
Retraction
tank
Hull unit
Hull unit flange
Tank flange
Bow mark
Emergency switch
This switch mayberemounted
on the starboard side if the
port side clearance is not
sufficient for switch operation.

Related product manuals