3. ADJUSTMENTS
3-13
3.5.3 TX Rate of operation
The TX rate of operation is the percentage of data output in one second, and it ap-
pears on the screen. If short intervals are assigned to many sentences, the rate of op-
eration increases as illustrated below.
Note 1: When outputting data without rest intervals between data, TX rate of operation
is 100%. In this case, wrong data may be shown on the receiver because it cannot
recognize intervals between data. Thus, do not output unnecessary data or set TX in-
terval to large value so that TX rate of operation becomes small.
Note 2: The GP-170 may not be able to display data from external equipment correctly
when the volume of TX data exceeds the GP-170's data handling capability. If this oc-
curs, lower the TX rate. Set the TX rate to 60% for the Temperature Indicator TI-20
and other equipment. This will create a gap between each data transmission to com-
pensate for occasions when data is not output regularly.
3.5.4 DATA1, 2, 3 or 4 output setting
1. Press the MENU/ESC key to open the main menu.
2. Select [7 I/O].
3. Select [1 Output Data1].
TX rate of operation: Low
TX rate of operation: High
TXTXTX
TX TX
TX
TX
TX