FURUNO
GP-1670F
SP - 2 E4477S01E
140611
5 INTERFACE
5.1 I/O port CAN bus, USB for maintenance
5.2 CAN bus PGN (NMEA2000)
Input 059392/904, 060928, 061184, 126208/992/996,
127245/250/251/258/488/489/493/496/505, 128259/267,
129025/026/029/033/038/039/040/538/540/793/794/798,
129808/809/810, 130306/310/311/312/313/314/577,
130828/830/831/832/880
Output 059392/904, 060928, 126208/464/992/996, 127258,
128259/267/275, 129025/026/029/033/283/284/285,
130310/312/830/831/832
5.3 NMEA 0183 (Data converter IF-NMEA2K2 required)
Input DPT, DSC, DSE, GGA, GLL, GNS, HDG, HDT, MDA, MTW, MWD,
MWV, RMC, ROT, RSA, THS, TLL, VDM, VHW, VTG, ZDA
Output DPT*, GGA, MDA*, MTW*, RMB, RMC, VHW*, VTG, ZDA
(*: external data required)
6 POWER SUPPLY
6.1 Display unit 12-24 VDC: 0.9-0.5 A
6.2 Rectifier (PR-62, option) 100/110/115/220/230 VAC, 1 phase, 50/60Hz
7 ENVIRONMENTAL CONDITIONS
7.1 Ambient temperature -15°C to +55°C
7.2 Relative humidity 93% or less at +40°C
7.3 Degree of protection IP56