2. WIRING, SETTINGS
7
2.1.2 Network Connection
Drop cable connection
A drop cable is connected to a backbone cable with T-type connectors*. The backbone cable is
of the "light" type. Attach a terminator at the ends of the backbone cable. Only two termination re-
sistors are required on an CAN bus network. More than two will degrade performance.
* Recommended type: LTWSS-050505-FMF-TS001 (LTW Technology, Inc.), or equivalent
Backbone cable connection
Use this connection method to connect the GP-330B at the final node in the backbone cable. Use
T-type connectors to connect equipment to the backbone cable.
GP-330B
Termination
Resistor: ON
T-connector
Cable Assembly
33-1209-01 (6 m)
33-1209-02 (10 m, option)
Power
(12 VDC)
T-connector
- NavNet 3D Series
- FI-50 Instrument
Power
(12 V)
T-connector
Backbone cable (max. 25 m)