2. WIRING, SETTINGS
9
2.2 NMEA 0183 Connection (Type B or N)
Wiring outline
Note: When connecting to equipment other than a Remote Display Unit or NAVnet vx2 series unit,
refer to the INTERCONNECTION DIAGRAM at the back of this manual.
Wiring procedure
Route the cable assembly to the display. Coil any excess cable and secure it with a cable tie to
prevent damage. Connect the GPS Receiver to your NMEA 0183 display.
NAVnet vx2
Series
Waterproof connectors by wrapping them with vulcanizing tape
and then vinyl tape. Bind tape ends with suitable cable ties.
GP-330B
Female
NMEA 0183 Cable Assembly
(22-910-03, 10 m, Standard supply for Type B, Optional supply for Type N)
Remote Display
Unit (RD-30)
Extension cable (MJ-A7SPF/SRMD-100, option)
max. length: 50 m
Female