EasyManuals Logo

Furuno IF-NMEA2K2 User Manual

Furuno IF-NMEA2K2
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
NMEA0183
Input
CAN bus Output
Sendin
g
C
y
cle
Normal
High
S
eed
AIS Zeus
129809
A
IS Class B “CS”
Static Data Report,
Part A
ID: 24
× × NP ×
129810
A
IS Class B “CS”
Static Data Report,
Part B
ID: 24
× × NP ×
VHW
127250 Vessel Headin
g
100ms 100ms × 100ms
128259 S
p
eed Throu
g
h Wate
r
1s 1s × 1s
VTG
128259 S
p
eed Throu
g
h Water 1s 1s × 1s
129026
COG & SOG, Rapid
U
p
date
250ms 250ms × 250ms
XTE 129283 Cross Track Error 1s 1s × 1s
ZDA
126992 S
y
stem Time 1s 1s × 1s
129033 Time & Date 1s 1s × 1s
PFECatt 127257
A
ttitude × 100ms × ×
PFEC,GPhve 65280 Heave × 1s × ×
PFEC,SDmrk 130830 Tar
g
et Information NP NP × NP
PFEC,SDtbd 130831
Target Bottom
Classification
NP NP × NP
PFEC,SDtfl 130832 Tar
g
et Fish Len
g
th NP NP × NP
*: This equipment can convert the BFT (Blue Force Tracking) use EIVDM
sentence (VDM sentence having EI talker) to CAN bus format. However, the
converted data can only be used with the FURUNO Multi Function Display and
software version combinations shown below.
TZT9/14/BB: Version 4.01 or later
TZTL12F/15F: Version 2.01 or later

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno IF-NMEA2K2 and is the answer not in the manual?

Furuno IF-NMEA2K2 Specifications

General IconGeneral
BrandFuruno
ModelIF-NMEA2K2
CategoryMedia Converter
LanguageEnglish