EasyManua.ls Logo

Furuno NAVpilot-700 - 2 Wiring; General Wiring

Furuno NAVpilot-700
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-1
2. WIRING
2.1 General Wiring
All units are connected to the Processor Unit. Separate the cables as far as possible from
the cables that transmit radio frequency or pulsed signals. At least one meter separation
is recommended.
Reversible pump
Solenoid valve
Hydraulic
linear drive
Power supply
12-24 VDC
Terminator BD-07AFFM-LR7001*
1
(supplied)
CONTROL UNIT
FAP-7001/7011
PROCESSOR UNIT
FAP-7002
RUDDER
REFERENCE
UNIT
FAP-6112
*
2
Remote
Controller
or
Distributor
Remote
Controller
or
Distributor
PC
NMEA PORT1 (Nav equip.)
NMEA PORT2 (Nav equip.)
CANbus (FI-50, PG-700, etc.)
*
1
: Attach the terminator to the empty
connector of the last control unit in the series.
*
2
: Not required for Fantum Feedback
TM
.
or
or
CONTROL
UNIT
FAP-7021
BD-07AF-07AF-LR-100
BD-07AF-07AF-LR-100
Terminator
BD-07AFFM-LR7001*
1
(supplied)
BD-07AFFM-LR-150
Contact signal out
Contact signal in

Other manuals for Furuno NAVpilot-700