AP2.1 GMDSS Radio Station
AP2-3
AP2.1.3 RC-1800-T/F (SSB Radiotelephone: FS-5000 400W)
1. RACK CONFIGURATION
(1) SSB Radiotelephone: FS-5000
(2) MF/HF DSC/Watch Receiver: DSC-60
(3) NBDP Terminal: DP-6
(4) Inmarsat C MES: FELCOM 12
(5) Printer PP-510 (2 sets)
(6) AC/DC Change-over Unit (RC-1800F: Standard supply / RC-1800T: Optional supply)
Battery Charger RC-1800F: BC-6158 / RC-1800T: BC-6158 (case: 6200)
AC/DC Power supply: RC-1800F: PR-850AR / RC-1800T: PR-850A
AC/DC Power supply: PR-300
2. POWER SUPPLY
(1) Main Source/ Battery Charger Source: 100/110/220 VAC, 1 phase, 50/60Hz, 44 A max.
(2) Reserve Source: 24 VDC, 50 A max. (For reduced emission)
3. ENVIRONMENTAL CONDITION
(1) Ambient Temperature: -15°C to +55°C
(2) Relative Humidity: 93% at +40°C
(3) Vibration: IEC 60945
(4) Waterproof: IEC 60945: IPX-0
4. COATING COLOR
(1) Cabinet: Munsell 7.5BG7/2
(2) Front Panel: Munsell N3.0
(3) Unit Panel: See respective specifications