2.1 MF/HF (150/250W) system
2-12
1) Setting MMSI
1. Turn on power, and press S1 (NMI SW) on CONTROL/MODEM board.
2. Then, * EEROM Clear * screen appears. Enter a password “652111”. Nothing
changes on the screen.
3. Select “MMSI CLEAR”, and press [ENT] key. Then, the default setting of MMSI
appears.
4. Enter the MMSI of the own ship, and press [ENT] key. Then, a message “PLEASE
POWER DOWN” appears. Turn off the power once, and then turn on again.
2) Setting SYSTEM menu
Canceling PROTECTION:
1. Press [SETUP] key while the DSC standby screen is selected.
2. Select SYSTEM using the cursor keys, and press [ENT] key.
3. Confirm that “PROTECTION ON” is highlighted on the bottom of the screen, and
then enter a password “652111”.
4. The indication changes to “PROTECTION OFF” to show the protection has been
canceled.
J7
J6
J1
J3 J8 J9
J4
J5
U5
S1
NMI SW
EEPROM
05P0702
S1(NMI SW)
Fig.2.1.2
Fig.2.1.3
Fig.2.1.4
* * * *
EEROM clear
* * *
NO CLEAR
MMSI CLEAR
ALL CLEAR
* *
System setup
* *
: ON
MMSI
WATCH RCVR
LINE OUT LEVEL
TX-KEY TIMING
RT PORT
: 123456789 FIXED
: MF/HF
: +0dBm
: AUTO
: MIF
PROTECTION