2.1 MF/HF (150/250W) system
2-13
Setting “SYSTEM”:
5. Set each item using the cursor keys and [ENT] key.
Table 2.1.8
Setting menu Setting
WATCH RCVR MF/HF
LINE OUT 0 dBm
TX-KEY
TIMING
AUTO
RT PORT MIF
REMOTE
STATION
ON
NBDP PORT ON
CH DET S
LEVEL
100
Setup menu SYSTEM
REGULATION International
3) Setting SCAN FREQ.
1. Press [SETUP] key with the DSC standby screen.
2. Select “SCAN FREQ” using the cursor keys, and press [ENT] key.
3. Then, “Scan freq setup” screen appears. Register ROUTINE and DISTRESS
frequencies. Register the international frequencies of 2 to 16 MHz for the
ROUTINE frequencies, and register all the DISTRESS frequencies.
- Distress frequency: minimum requests, 2 M + 8 M + at least one freq.
- Routine frequency: depend on costumer requests
Fig.2.1.5
* *
Scan freq setup
* *
ROUTINE
F1:2M-INTL
F3:4M-INTL
F4:6M-INTL
F6:16M-LCL2
DISTRESS
2M:FIXED
4M:ON
6M:ON
8M:FIXED
12M:ON
16M:OFF
F2:2M-USR3
F5:12M-LCL1
OFF
2MHz
4MHz
6MHz
8MHz
12MHz
16MHz
18MHz
22MHz
25MHz
OTHER
INTL
LOCAL1
LOCAL2
User CH1
:T12577.5/R12657.0
:T12578.0/R12657.5
:T12578.5/R12658.0
:T12345.0/R12345.0
F1-6
[ENT]
[ENT]
2-25MHz
ON