2.1 MF/HF (150/250W) system
2-15
2.1.3 DP-6 system setting
Set nine- or five-digit ID number, answerback code, and “System” in [F6] menu.
Set and confirm the items in Table 2.1.10. Set the other items as per customer’s
requests.
Table 2.1.10
Function Menu Default Setting Note
F3:Operate 6:Manual Reception AUTO AUTO
5:Answerback
Code Entry
MMSI+
CS(4 Char.)+X
Password:
ANSWER CODE
(Caps Lock)
6:Group ID Entry
(4/5 digit)
7:Group ID Entry
(9 digit)
8:Select ID Entry
(4/5 digit)
X1 –X5
F5:Station
9:Select ID Entry
(9 digit)
MMSI
Password: ID CODE
(Caps Lock)
*Slave Delay 5 msec 5 msec
*BK Timing Pre tone 10 msec 10 msec
*Post Tone 0 msec 0 msec
*Mute Timing Pre BK 0 msec 0 msec
*Post BK 0 msec 0 msec
*Modem Output Level 0 dBm 0 dBm
Password: DP6
(Caps Lock)
MIF Tune OFF OFF
Freeze OFF OFF
AGC OFF ON or OFF
FS-1562:OFF,
FS-5000:ON or OFF
Emission ON ON
TX/RX MSG Save OFF ON or OFF
Edit Before sending OFF On or OFF
Time System UTC UTC
Time & Date ---
F6:System
Display Mode Normal Normal
Language Normal Normal
Fn+F1
Printer PP-510 PP-510
Password: DP6
(Caps Lock)
Note) Do not change any of shaded items.