2.2 MF/HF (400W) system
2-19
2.2.1 FS-5000 system setting
1) Changing and checking system settings
Check settings in the system channel list in Table 2.2.1. Set the system channel “9982”
to “1: Yes” without fail. The settings in the other channels are factory-default settings.
Make the operation-related settings as per customer’s requests.
Setting procedure:
1. Press [STO] key.
2. Enter “System channel” to be set and press [ENT] key.
3. Enter the displayed setting values and press [ENT] key.
Note) To check the system settings, press [RCL] 9999 [ENT].
Table 2.2.1
Setting System
channel
Function
0 1 2 3 4
9904 Class of emission on2182kH AM SSB SSB FIX
9905
TX TUNE
*Auto:Tuning is done when
setting Tx freq.
Enable Disable *AUTO
9913 Tx delay time 10 msec
9917
50Ω BK
ON/OFF ON
9928 Minimum output power
Less
then
60W
60W or
more
9930 Data to REM-1 terminal MIF TBUS CIF NMEA MIF2
9931 Data to REM-2 terminal MIF TBUS CIF NMEA MIF2
9932 Data to REM-3 terminal MIF TBUS CIF NMEA MIF2
9934
Class of emission of Tx/Rx, when unit
connected to REM-1 is once keyed.
No
change
SSB AM TLX
9935
Class of emission of Tx/Rx, when unit
connected to REM-2 is once keyed.
No
change
SSB AM TLX
9936
Class of emission of Tx/Rx, when unit
connected to REM-3 is once keyed.
No
change
SSB AM TLX
9937
Class of emission of Tx only while unit
connected to REM-1 is once keyed.
No
change
SSB AM TLX
9938
Class of emission of Tx only while unit
connected to REM-2 is once keyed.
No
change
SSB AM TLX
9939
Class of emission of Tx only while unit
connected to REM-3 is once keyed.
No
change
SSB AM TLX
9953 Operation on AM mode Tx/Rx Rx Disable
9982
ANT BK relay or Rx ANT installation
(Both function of 9913 and 9917 are
determined.)
No
- 9913:
30 msec
- 9917:
ON/OFF
Yes
- 9913:
10 msec
- 9917:
ON