EasyManua.ls Logo

Furuno RC-1800T - Q & a; Charger BC-6158 Does Not Work; No Power to FS-5000;Breaker Trips When Transmitting

Furuno RC-1800T
150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2 Q & A
6-6
6.2 Q & A
1. Charger BC-6158 does not work.
1) Is battery charged even with the switch set to [Manual].
Does the AC input relay, K1 in BC-6158 operate?
NO - If CR1 (Charge) on 05P0607 board lights, the charging control circuit
functions.
- Check wiring between BC-6158 and 05P0607 board.
- Check that AC power supply relay on BC-6158 is normal.
- If CR1 on 05P0607 board does not light, 05P0607 board may be fefective.
YES - Rectifier or AVR circuit on BC6158 may be defective.
2) “Auto” function does not work even though the battery switch is set to [Auto.]
Is battery charged with the battery switch set to “Manual?”
NO - See item 1).
YES - Defective 05P0607 board or adjustment of 05P0607 required
Note) With the “Auto” function, the battery charger starts when the battery voltage
drops to 24.5– 25.0 V and stops working when the voltage reaches to 27.5 V. Refer to
page 4-13 for adjustment.
2. No power to FS-5000/Breaker trips when transmitting
Check breakers of PR-850A(AR) and FS-5000T do not trip.
If power is interrupted when transmitting,
- Check that transmission power does not exceed the rating.
Collector current is approximately 18A and collector voltage is less than 40V
when the HF band signal is transmitted in 400 W
If input voltage or Vs value drops from 24V to less than 21V during
transmission, change the power cable between PR-850A (AR) and FS-5000T
with bigger one.
For example, change cable of 8 sq. to 14 sq.
- Check that power supply voltage to PR-850A(AR) does not drop more than 10%
during transmission.
If the voltage drops, replace the power cable with a bigger one or change supply
voltage. For example, if power supply is 100Vac, change it to 200Vac. Of course,
PR-300, PR-850A(AR), and BC-6158 must be modified according to supply
voltage.