6.2 Q & A
6-9
7. DP-6/FELCOM 12 shows error message.
When the following communication error messages are shown in communication with
IB-581, try turning power OFF and ON.
DP-6: “Check interconnection between terminal and main unit”
FELCOM 12: “No response from communication unit”
Open the battery control panel and the power switches of the main unit of DP-6,
FELCOM 12 and communication control unit (IC-212) are accessible. Turn off DP-6,
IC-212, and IB-581, and turn them on again.
Fig. 6.2.2 Location of power switches
8. DSC-60 shows error message.
If “Watchdog error, Please power OFF”, “No response RT” are shown or keys do not
work, try restarting the unit or switching power OFF and ON. If restarting cannot solve
the problem, conduct “EEROM Clear”.
Remember that after EEROM clear, MMSI and system setting are necessary.
How to conduct “EEROM Clear” (Refer to page 7-6.)
1) Press S1 (NMI) on CONTROL/MODEM board.
2) Input password of “652111” to memory clear display.
3) Select [ALL CLEAR] and press [ENT] key.
4) Enter MMSI.
5) Turn off power and turn it on again.
6) Carry out system setting.
Power supply switch
- DP-6
- IC-212