1. INSTALLATION
1-21
7. Secure the cable to the cable clamp, referring to the figure below.
Note: In cases where the WAGO connector is connected to the cable before the cable
is passed through the cable clamp, the cable clamp can be adjusted to allow connec-
tion. Adjusting the cable clamp as outlined in the figure below voids the IPx5 water-
proof rating of the clamp and the unit.
Without Water Proof Kit With Water Proof Kit
Top view of cable clamp
Supplied cable
Z-#26X2P+0.3SQX1PL
Equivalent cable for JIS cable (TTYCSLA-4)
Slot
Slot
Cable
gasket
Cable
gasket
Cable tieCable tie
Cable tieCable tie
Cable tieCable tie
Cable clampCable clamp Cable clampCable clamp Cable clampCable clamp
With three cable ties With two cable ties With a single cable tie
Secure the cable gasket also
with a cable tie.
Wind cable ties through the slots.
Wind a cable tie outside of the
cable clamp.
Cut along “V”-shaped
indent using a wire
cutter or similar tool.
Slide the clamp over
the cable.
To keep the IPx5 rating, remove the WAGO connector, then repeat the procedure above.