3. HOW TO SET UP THE EQUIPMENT
3-17
*: This item is only available for DFF3 users.
When [Transducer Setup Type] is set to [Model] and connected to DFF3
When [Transducer Setup Type] is set to [Manual]
Motion sensor menu
Adjust these settings to view a clearer picture of the seabed, fish schools etc when in
moderate-to-rough seas.
Note 1: For connection of NMEA 0183 equipment, ask your dealer to set up the equip-
ment.
Note 2: To use the heaving function, the following settings are required at the satellite
compass. For the setting procedure, see the operator’s manual for your satellite com-
pass. Settings for SC-30 are done from the [IF-NMEASC] menu, settings for SC-50/
110 are done from the [DATA OUT] menu.
[Low Frequency Max] Display the low frequency maximum.*
[Reset Default Set-
tings]
Reset the Transducer Setup menu settings to default. [OK], [Cancel]
Menu item Description
Options
(setting range)
[High Frequency] Select the model and frequency (HF & LF) of the connected
transducer from the appropriate drop down menu.
[Low Frequency]
Menu item Description
Options
(setting range)
[High Frequency (KHz)] Set the kHz frequency for high frequency. Setting ranges vary
depending on the transducer connected.
[Transducer Power HF] Set the transmission power for high frequency.
Note 1: This menu item is available only for
DFF1, DFF1-UHD, BBDS1 and internal fish
finder users.
Note 2: For DDF1-UHD users, when the con-
nected transducer TDID is not supported by the
DFF1-UHD, the setting is fixed as [1000].
[600], [1000]
[Band Width (HF)] Set the bandwidth for high frequency.
Note: This item is only available for DFF3 users
when the Transducer type is set to [Manual].
[10] to [100]
[Low Frequency (KHz)] Set the kHz frequency for low frequency. Setting ranges vary
depending on the transducer connected.
[Transducer Power LF] Set the transmission power for low frequency.
Note 1: This menu item is available only for
DFF1, DFF1-UHD, BBDS1 and internal fish
finder users.
Note 2: For DDF1-UHD users, when the con-
nected transducer TDID is not supported by the
DFF1-UHD, the setting is fixed as [1000].
[600], [1000]
[Band Width (LF)] Set the bandwidth for low frequency.
Note: This item is only available for DFF3
users.
[10] to [100]
Menu item Description