Error Code Error Name Description Action
435 DRU Device
Recording Verify
Failure
Serial data from DRU are not
recorded correctly because the DRU
format is out of order.
Restart VDR. If error occurs again, request
service to reformat DRU.
436 BackupHDD Device
Recording Verify
Failure
Serial data from BackupHDD are not
recorded correctly because the
BackupHDD format is out of order.
Restart VDR. If error occurs again,
Request service to reformat BackupHDD.
437 Fatal System Failure Fatal system error. This indicates
that VR-3000/S can not be rebooted
automatically.
Restart VDR manually. If VR-3000/S does
not recover, request service.
438 VDR System
Information Error
VDR system information can not be
acquired. Usually, this error is
recovered automatically.
If error is not recovered automatically,
restart VDR. If VR-3000/S does not
recover, request service.
3.3 Testing Display of Remote Alarm Panel
Press the TEST button on the RAP to check that all LCD segments are displayed properly.