2-1
2. WIRING
The illustration on this page shows the general connection of the VR-7000/7000S. For
detailed information, see the interconnection diagram. Many of the cables mentioned
are JIS (Japanese Industrial Standards) cables. If not available locally, use the equiv-
alent. See the cable guide in the Appendix for how to select equivalent cables.
Radar, ECDIS, etc.
NR203PF-VV1.25
NR203PF-VVS1325
100-230 VAC
STP (CAT5) cable
MC1.5-W-L cable,
0.6/1/2/3 m
Data
Collecting
Unit (DCU)
VR-7010
Fixed DRU
VR-7020*
2
Float-free DRU
VR-7021F*
2
Video LAN Converter
IF-7100
24 VDC
PC
Live Player V5
VR-7030
100-230 VAC
Remote Alarm Panel
VR-7017
Microphone
VR-7011
Waterproof Microphone
VR-7012W
Max. 8 units
Radar/ECDIS display
100-230 VAC
Max. 2 units
Switching HUB
HUB-100
Sensor Adapter
MC-3000S
Sensor Adapter
MC-3010A
MC-3020D
Junction Box
VR-7022F*
2
AIS
TTYCSLA-1Q
GYRO
GPS
TTYCSLA-1
LOG
ECHO
SOUNDER
ANEMOMETER
ALARM
NAVTEX
TTYCSLA-1Q
TTYCSLA-1
TTYCSLA-1
TTYCSLA-1
TTYCSLA-1
TTYCSLA-1
Intelligent HUB
HUB-3000
STP (CAT5) cable
TTYCSLA-1
STP (CAT5) cable
FR-FTPC-CY,
10/20/30/50 m
FR-FTPC-CY,
10/20/30/50 m
DPYC-1.5
DPYC-1.5
Network
equipment
Sensor
equipment
DPYCY-1.5
DPYCY-1.5
TTYCSLA-4
TTYCSLA-1Q
DPYC-1.5
FR-FTPC-CY,
10/20/30/50 m
TTYCYSLA-1Q
FR-FTPC-CY,
10/20/30/50 m
FR-FTPC-CY,
10/20/30/50 m
FR-FTPC-CY,
10/20/30/50 m
Sensor
equipment
Power Supply Unit*
1
PSU-011
DPYC-1.5
*
1
: For Russian vessel only
Junction Box
IF-8530
Serial Interface: Max. 2 ch
TTYCS-1QIEC 61162-1/2
DPYC-1.5
- GPS
- Speed log
- Heading
- Echosounder
- Autopilot
- Engine telegraph
- Steering gear
- M/E remote system
- Main air compressor
- Bow thruster
- Shell door system
- Watertight doors
- Fire doors
- Anemometer
- Fire ditection
- Main alarms
- Others
Serial Interface: Max. 6 ch
TTYCS-1IEC 61162-1
Analog IN: Max. 16 ch
TTYCS-1
Digital Contact IN: Max. 64 ch
TTYCS-1
STP (CAT5) cable
Junction Box
IF-8540
or
Sensor
equipment
*
2
: When using the VR-7000S, select
either the “VR-7020” or the “VR-7021F and
VR-7022F”.
VHF Audio
Max. 2 ch

Other manuals for Furuno VR-7000