3. SETTING UP THE EQUIPMENT
3-6
3.6 Timeout Settings for Serial Input Signal
Be sure to set the timeout settings for all serial channels. If the timeout setting is not
adjusted, the serial communication error alert does not occur when serial connected
equipment is disconnected.
You can adjust the timeout settings from the VDR Maintenance Viewer*. The timeout
settings must be higher than the transmission rate of the connected equipment.
After completing the timeout settings, it is recommended that you make a copy of the
following table and make a note of the settings, then put the table on a wall near the
remote alarm panel.
*: For how to use the VDR Maintenance Viewer, see the Instruction Manual (OME-
44852).