3. HOW TO BACK UP CONFIGURATION DATA
3-3
3.3 How to Restore the Default Settings
The procedure below shows how to restore default setting data to the DRU (Fixed,
Float), Long Term Device, CF and VDR Maintenance Viewer.
1. Connect the PCU and DRU to the DCU.
2. Turn on the VDR and wait four minutes.
3. Do the following to download the DefaultConfig.xml file from the VDR to the PC.
a) Open Internet Explorer
®
on the PC.
b) Input ftp://172.31.16.200/pub/ to access the VDR from the PC.
c) Copy the DefaultConfig.xml file to the desktop of the PC.
4. Open the VDR Maintenance Viewer on the PC.
5. Enter 172.31.16.200 (or 172.31.16.202) in the IP address box in the [Maintenance
Login] dialog box.
6. Check [Serviceman], enter the password, then click the [OK] button.
7. Select [Maintenance], [VDR Config Management] and [Import from].
Note: Use only the default configuration file (DefaultConfig.xml).
8. Select the DefaultConfig.xml file from the desktop then click the [Open] button.
9. Click the [Upload] button.
10. Click the [Write] button.
Note: To restore default VDR system settings, click the [Default] button on the [VDR
Config Management] dialog box.