61
GOV. BASIC screen 2/6
Go to 3/6 from any cursor position
(3) Pole Num.: Pole number
This parameter is used when using a direct phase sensor attachment to
a brushless motor lead. Input the motor pole count as specified by the
brushless motor manufacturer. When using any revolution sensor other
than a direct phase sensor type, set the pole number to 2p.
Note: For nitro use, set to 2p.
Note: The input signal range of the CGY760R is 0.0v-3.0v. Exceeding
this voltage range may cause damage to the CGY760R.
Setting ranges: 2 ~ 24P Initial value: 2P
(4) Servo Type
Select the throttle servo type. Digital servos offer the best response.
Move the cursor to "Servo Type"
by pressing the [ /+] or [ /-] key
and
press the [Enter] key to enter the setting mode. Select the servo type with
the [
/+] or [ /-] key
. Pressing the [Enter] key
exits the setting mode.
Setting: Analog / DG:1520 Initial setting: Analog
WARNING
The servo type parameter within the CGY760R must match the
type of servo you are using. Incorrect settings may damage the
CGY760R or the servo. An incorrect setting may also result in the
loss of control during flight.
From 1/6
CAUTION
There is a danger of heavy loads being applied
to the rotor rotating at high speed. Dropout of
the rotor blade, damage of the head, etc., may oc-
cur. Do not set the rotation speed to a value that
exceeds the strength limit of the helicopter and
rotor.