Seite 18
4.4. Before starting any maintenance operation on the heater disconnect from
both gas and electrical suppliers.
4.5. If the unit has not been used for a long period we advise that a technician
carries out a general check up before using. It is important to control the
following:
4.5.1. Periodically check the gas supply hose conditions and, should it be
changed, use only original spare parts.
4.5.2. Check the starting electrode position (see Fig.5).
4.5.3. Check the connections of the safety thermostat and of the thermocouple:
they must always be clean.
If necessary clean the fan blade and the inside of the heater using compressed
air.
5. TROUBLESHOOTING
PROBEM
SOLUTIONS
The motor does
not work
Check the terminal board with a tester
Wait about one minute then restart
The motor works,
but the burner
does not light up
and after few
seconds the
heater stops
Open the gas tap
Use a new cylinder
Remove the nozzle and clean it.
Check that the solenoid valve works
Check the position of electrode
The burner lights
up but after few
seconds the
heater stops
Check and connect properly
Check and connect properly
Replace the safety device
The heater stops
during operation
Check the pressure reducer and if
required replace it
Check that the motor works properly
Check and use a larger cylinder or
two cylinders connected together.