Luxor Overview
Glossary of Terms
Group: An addressed set of lights that is designated numerically
and controlled as a set by the controller
Theme: A predetermined set of groups, intensities, and colors
called to action by the program or manual functions
Fixture/Luminaire: Light unit that contains an FX Luminaire
LED board or device with FX Luminaire zoning, dimming, or
color capabilities
Intensity: Value indicating the measurable amount of brightness,
from 1% to 100%
Event: The initiation, adjustment, or conclusion of a selected
theme or group with specic intensity and/or color settings
Duration: The length of time an event will run
Hue: The primary attribute of a color; it is represented by a
numeric value between 0 and 359
Saturation: The richness of a color mixed with white light,
from 0% to 100%
Color: The visual combination of hue and saturation
Primary Controller: Luxor Controller containing a facepack
Satellite Controller: Controller without a facepack
Safety Information
These cord-connected units consist of step-down, isolated,
two-winding-type transformers, circuit breakers, and associated
circuitry intended to supply power to low-voltage, submersible
lighting xtures.
WARNING — Risk of Electric Shock. Install the power unit 5'
(1.5 m) or more from a pool or spa and 10' (3 m) or more from a
fountain. Where the power unit is installed within 10' (3 m) of
a pool or spa, connect power unit to a GFCI-protected branch
circuit. Do not use an extension cord when connecting the power
unit to the 120 V source. The grounding conductor shall be
12 AWG (2.05 mm) minimum. The outdoor power unit shall be
connected to a GFCI-protected, hooded, ush-type cover plate
receptacle marked “Wet Location” while in use.
Caution: The supply circuit for the landscape lighting system
shall be protected by a Class A–type ground fault circuit
interrupter, unless it is provided with the landscape lighting
system. This device is accepted as a component of a landscape
lighting system where the suitability of the combination shall be
determined by local inspection authorities having jurisdiction. Do
not connect two or more power supplies in parallel. Not for use in
dwelling units. This presents a risk of re. Do not place insulation
under the terminal plate. Check the connector aer installation.
Circuit Protection
12.5 A for a 150 W controller
22 A for a 300 W controller