G.S.I DC Installation and Operation Guide
16
Connecting a Rain Sensor, Flow Meter, and
Fertilizer Meter
The GSI unit supports the following input devices:
Rain sensor
Flow meter (pulse type)
Fertilizer meter
To connect the input wires:
Rain sensor Connect one of the rain sensor wires to the connector
labeled Rs, and connect the second sensor wire to one of the
connectors labeled C on the INPUT line. The polarity of the wires is
not important.
Flow meter Connect one of the flow meter wires to the connector
labeled Ws, and connect the second wire to one of the connectors
labeled C on the INPUT line. The polarity of the wires is not
important.
Fertilizer meter Connect one of the fertilizer meter wires to the
connector labeled Fs, and connect the second wire to one of the
connectors labeled C on the INPUT line.
See Figure 12 (example only. Different models may vary).
Note: You must define the rain sensor, flow meter, and
fertilizer meter in the G.S.I web application before you can use
them.
Inserting a SIM Card
The SIM card case is located on the upper left side of the controller
board.