Page 22 709-RVC NLP Manual
16. If equipped, connect the pump switch as required.
17. Verify that the battery voltage reads correctly. If it appears
low, make sure you have good wiring for the 12 volt power
and the ground.
18. The common alarm output provides a connection to ground
when the alarm is active. The maximum current that can be
put through the alarm output is 100mA, be sure to use a
relay if more current is required. Program and test the alarm
output to ensure that it functions as desired.