4. Connect output terminals AC OUT 1, AC OUT 2 to the film.
5. Turn the AC mains ON again. During this step, make sure the ON/OFF
switch is in the OFF position, otherwise the unit can enter into a latched
up state. If something like this happens remove the AC mains, move the
switch to the OFF position and restore the power supply to the unit.
6. Toggling the switch to the ON position will turn the film to a
transparent state.
7. To turn the film translucent, toggle the switch to the OFF state.
Note: The same functionality can be
achieved by connecting the ON/OFF
terminal to the AC LINE through a relay.
Note: You can also use Gauzy’s ON/OFF Touch Panel
for this configuration.
Dry Contact Control Interface
ON/OFF
Line
110/220VAC
ON/OFF
Line
110/220VAC
ON/OFF
AC OUT
FREQUENCY
STATUS
CASCADE
DRY
CONTACT
COMMON
N.C
OUT OK
ALARM
COMMON
OUT
COMMON
IN
MUTE
DO
COMMON
DT/ON-OFF
LINE
32 HZ
LINE/2
POWER IN
HV CNTL
G
RO
U
N
D
N
.C
N
EU
TRAL
N
.C
LIN
E
O
N
-O
FF
DT
D
O
Film Out
Line
Neutral
Ground
AC mains
110/220VAC
ON/OFF
Wall Switch
Gauzy ON/OFF
Touch Panel
ON/OFF
Wall Switch
Film