Table B6: System Feature Event Trigger Numbers
Feature State
Trigger
No.
Phone Test initiated 225
AC Failure for 15 minutes 226
CPU Low Battery detected (excluding first minute after power-up) 227
Auto Phone Test begun 228
Receiver Failure detected 229
Back In Service alarm (AC loss, battery drain, then AC restore) 230
Phone Failure detected 231
Buffer Full detected 232
Two Trip Error detected 233
System Tamper alarm (40 incorrect code entry keystrokes) 236
Freeze alarm 237
No Activity alarm 238
Fire Panic alarm 239
Police Panic alarm 240
Auxiliary Panic alarm 241
Opening Report occurred 242
Closing Report occurred 243
Latchkey Opening or Closing occurred 244
Duress alarm 245
Force Armed Report occurred 246
Fire in Partition alarm 247
Recent Closing Report occurred 248
Sensor Test entered 249
Table B7: Response Characteristics
Response
Characteristics
Description
Momentary trip time
The point will remain activated for nn seconds (n is 1-12 seconds).
The default is 4 seconds
3 minute trip time The point will remain activated for 3 minutes
Siren-time trip time The point will remain activated while the interior siren is sounding
Sustained trip time The point will remain activated for the duration of the event
Siren pattern
The point will activate and deactivate according to the current
alarm type:
Auxiliary -- fast on/off/on
Police -- constant on
Fire -- repeating)
Trip delay The point will activate 30 seconds after the trigger event occurs