AquaTrans™ AT600 User’s Manual 13
Chapter 2. Clamp-On Fixture and Transducer Installation
2.1.1 Transducer Spacing = 32 to 250 mm or 50 to 320 mm, Traverses = 2, Fixtures = 1 (cont.)
5. See Figure 14 below for an example of a completed installation. In this drawing, LSL is the Lower
Specified Limit and
USL is the Upper Specified Limit for the installation.
Note: For a one-fixture installation,
LSL is 0 on the scale and USL is 250 mm for a 2 MHz transducer or 320 mm
for a 1 MHz or 0.5 MHz transducer. The transducer spacing is measured from
LSL to a point USL.
Figure 14: Installation for 2 Traverses with 1 Fixture
6. Your clamp-on fixture and transducer installation is now complete. To wire your AT600 flow meter,
proceed to “Wiring the AT600 Electronics” on page 23.
UPSTREAM DOWNSTREAM
Spacing
LSL USL