Section 19 - Appendix B–Filter Board Options PWA 79562-01 and PWA 105521-01
69
CHANNEL A -
CHANNEL B -
W88
W90
W43
W56
W54
W57
W55
W77
W53
W75
W52
W74
W51
W73
W50
W72
W49
W71
W48
W70
W47
W69
Hz
CPM
I
I
I
I
I
R
R
R
R
R
R
R
R
R
R
I
I
R
R
R
R
R
I
I
I
R
R
I
I
I
I
R
I
I
R
R
R
I
R
R
R
I
I
R
I
I
I
R
I
I
R
R
I
R
R
417
463
500
543
588
25020
27780
30000
32580
35280
I
I
I
I
I
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
I
I
R
R
R
R
R
I
I
R
I
R
I
R
R
I
I
I
R
I
I
I
R
I
I
R
I
I
I
I
R
I
R
R
R
625
676
758
833
926
37500
40560
45480
49980
55560
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
R
R
R
R
I
I
I
I
R
I
R
R
R
I
R
I
R
R
I
R
I
I
R
R
1000
1087
1163
1250
1351
60000
65220
69780
75000
81060
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
R
R
R
R
I
I
R
R
R
I
R
R
R
R
R
R
R
I
R
R
R
R
I
R
R
I
I
1515
1667
2083
2500
3333
90900
100020
124980
150000
199980
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
R
R
R
R
I
I
I
I
R
I
R
I
R
R
R
R
R
R
I
R
R
R
R
R
I
I
I
I
I
R
R
R
R
I
R
I
4167
5000
6250
8333
10000
250020
300000
375000
499980
600000
I
R
R
I
I
I
I
I
I
R
R
R
R
R
R
R
R
R
I
R
R
R
R
R
I
R
R
I
R
R
I
R
R
12500
14915
22372
750000
894900
1342320
The -3 dB corner frequency occurs at 1.06 X the frequencies listed in this table.