EasyManua.ls Logo

GE IC3645SR3R404P2 - Page 26

GE IC3645SR3R404P2
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 26
July 1999
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-23
Motor field current is high on start up in
the reverse direction.
This status code will be displayed when the current
draw in the motor field is too high at start up in the
reverse direction.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective control.
= Replace controller unit.
NO GRAPHIC FOR THIS
STATUS CODE
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-24
Motor field current is high on start up in
the forward direction.
This status code will be displayed when the current
draw in the motor field is too high at start up in the
forward direction.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective control.
= Replace controller unit.
NO GRAPHIC FOR THIS
STATUS CODE

Table of Contents

Related product manuals