DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 43
July 1999
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-86
The control cannot complete the
potentiometer auto calibration routine
due to potentiometer settings which are
out of range.
This status code will be displayed when any of the
potentiometer values do not meet the criteria outlined
below during the potentiometer auto calibration
routine.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
SYMPTOM
“-86” status code appears on the dash display.
POSSIBLE CAUSE
Accelerator, steer angle or brake pots require
external adjustment.
Accelerator, steer angle or brake pots are
currently set out of the range identified below.
Defective controller unit.
•= Replace control.
Accelerator
Pot
•= Wiper voltage is greater than
4.5 volts
•= Span voltage is less than 2.6
volts
Steer Angle
Pot
•= Wheel must be straight
•= Wiper voltage cannot be
between 1.90 and 2.40 volts
Circuits valid
for
Traction
Controller
Brake Pot
•= Low brake pot wiper value of
less than 0.75 volts
NO GRAPHIC FOR THIS
STATUS CODE
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-99
Controls are going through the start up
sequence.
This status code will be displayed when the key
switch is initially turned on.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Controls are going through the start up
sequence.
•= Wait until controls complete start up
sequence.
NO GRAPHIC FOR THIS
STATUS CODE