DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL Page 54
January 1999
PUMP
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-151
Capacitor volts are low before the line
contactor closes. (Internal card function
during precharge)
This status code will be displayed during “key on”
when the capacitor volts is less than 85% of battery
volts at initial key switch on.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM:
Line contactor does not
close when Capacitor does
not pre-charge.
POSSIBLE CAUSE:
Defective control fuse.
•= Check control fuse for
open circuit, replace fuse,
if necessary.
Defective control.
•= Replace controller unit.
Note: Repeated
charging/discharging the
capacitors during
troubleshooting will cause
status code 51. Also do not
connect any
loads to the
load side of the line
contactor.
FU5
KEY SWITCH
P1 P2 P10
P6 P5P16
94 INPUT
94 INPUT
90 INPUT
P13
P11
91 INPUT
BRUSHWEAR OUTPUT - P14
P14
OVER TEMP OUTPUT - P20
P15
92 INPUT
P12
P9
95 INPUT
P8
95 INPUT
FU6
P19
P20
P21P4 P3
93 INPUT
93 INPUT
TO TRACTION
CARD
SPEED LIMIT 1
SPEED LIMIT 2
SPEED LIMIT 3
SPEED LIMIT 4
TO
TRACTION
P10 - BDI
POWER CONNECTIONS
POS A1
NEG A2
FIELD
ARMATURE
LINE
+
-
FU1
PUMP
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-157
Controller “motor current sensor” input
voltage polarity check.
This status code will be displayed when the voltage
input to PZ13 and PZ12 is of the wrong polarity.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM:
Pump control will not
operate.
POSSIBLE CAUSE:
Control is defective.
•=Replace controller
unit.
FU5
KEY SWITCH
P1 P2 P10
P6 P5P16
94 INPUT
94 INPUT
90 INPUT
P13
P11
91 INPUT
BRUSHWEAR OUTPUT - P14
P14
OVER TEMP OUTPUT - P20
P15
92 INPUT
P12
P9
95 INPUT
P8
95 INPUT
FU6
P19
P20
P21P4 P3
93 INPUT
93 INPUT
TO TRACTION
CARD
SPEED LIMIT 1
SPEED LIMIT 2
SPEED LIMIT 3
SPEED LIMIT 4
TO
TRACTION
P10 - BDI
POWER CONNECTIONS
POS A1
NEG A2
FIELD
ARMATURE
LINE
+
-
FU1