Performance Data Sheet
SmartWater Filtration System
t,,IWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(!00% safety factors built in for unmetered usage)
USEPA Influent
Parameter MCL Challenge Concentration
Chlorine - 2.0mg/L+ 10%
T&O - -
Particulate** - _>10,000particles/mL
Standard No. 42: Aesthetic Effects
Influent Effluent
Average Average Maximum
1.96mg/L 0.06mg/L 0.11mg/L
6,400,000#/mL 58,833#/mL 150,000#/mL
% Reduction
Average Minimum
96.77% 94.74%
99.14% 97.97%
Min. Required
Reduction
>50%
_>85%
Parameter
Turbidity
Cgsts
Asbestos
Leadat pH6,5
Leadat pH85
Mercurgat pH6.5
Mercurgat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
USEPA
MCL
0.5NTU
_>99.95%Reduction
_>99%Reduction
0,015mg/L
0,015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0,003mg/L
0.005mg/L
0,040mg/L
0,075mg/L
0.003mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11+ 1 NTU***
Minimum50,000L
107to 108fibers/L;>10pm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
10,5 NTU
118,750 #/L
57 MF/L
0.1567 mg/L
0,1433 mg/L
0,0059 mg/L
0,0057 mg/L
0,0367 mg/L
0,0020 mg/L
0,2033 mg/L
0,0160 mg/L
0,0145 mg/L
0,0830 mg/L
0,2283 mg/L
0,0087 mg/L
Effluent
Average
0,14NTU
<1 #/L
0,996MF/L
<0,001mg/L
<0,001mg/L
0,000350mg/L
0,000325mg/L
0,00023mg/L
<0.00002mg/L
0,00337mg/L
0,00100mg/L
0.000500mg/L
0,001000mg/L
0.000500mg/L
<0,0005mg/L
Maximum
0.28NTU
4#/L
<1 IVlF/L
<0.00t mg/L
<0.00t mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002mg/L
0.011000mg/L
0.001000mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
<0.0005mg/L
% Reduction
Average Minimum
9854% 97.20%
>99.99% > 99.99%
99.60% 99.39%
99.36% 99.29%
99.30% 99.29%
94.70% 87.50%
93.20% 89.29%
9934% 98.67%
99.00% 98.95%
98.32% 94.50%
93.44% 91.67%
9651% 95.83%
98.78% 98.65%
99.78% 99.77%
94.22% 93.33%
Min. Required
Reduction
0.5NTU
_>99.95%
_>99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0,04mg/L
0.075mg/L
0.003mg/L
Tested using a flaw rate af 0.50 gpm; pressure af 60 psig; pHaf 7.5 +_0.5; temp. af 68 ° +_5°F (20 ° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelametric Turbidity/units
Operating Specifications
[] Copmcitg: certified for up to 300 gallons (1135 I);up to six months for models without a replacement filter indicator light;
up to one gear for models with a replacement filter indicator light
[] Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
[] Temperature: 33-100°F (0.6-38°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
[] Flush new cartridge ot full flow for 5 minutes to purge out trapped air.
[] Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
[] Installation instructions, parts and service availabilitg, and standard warrantg are included with the product when shipped.
[] This drinking water sgstem must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
[] Do not use with water that is microbiologicmllg unsafe or of unknown qumlitg without adequate disinfection before or
after the sgstem. Sgstems certified for cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
[]The contaminants or other substances removed or reduced bg this water treatment sgstem are not necessmrilg in gour water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard labormtorg conditions, actual performance mag varg. Sgstems must be
installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
Sgstem Tested and Certified bg NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercurg and Toxaphene Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cgst and Asbestos Reduction