Group
Value  Displayed  Failure Code Definition  Setting Criteria 
External Interaction (700 thru 799) 
F700  0 7 0 0 
Stuck keys On ICID/ACM/ (Dispenser Boards)
 
Stuck Key is present on ICID/ACM.  Only send 
once per each stuck key.  
 
F701  0 7 0 1 
Stuck Keys on Internal Temp Board
 
Stuck Key is present on Internal Temp.  Only 
send once per each stuck key.  
 
F702  0 7 0 2 
 
Stuck Key is present on Deli Pan.  Only send 
once per each stuck key
 
F703  0 7 0 3 
Deli Pan Temp Board and Door Closed 
FF Door is closed and a Key Input is detected 
F704  0 7 0 4 
Key Inputs on Deli Pan/FP Board and Door Closed
 
FF Door is closed and a key input is detected
 
F705  0 7 0 5 
Auto fill Communication Error
 
AutoFill Module not communicating properly
 
F706  0 7 0 6 
 
The Version of the Auto fill module is not 
compatible with the ACM Version
 
F707  0 7 0 7 
Comm Communication Error 
COM Module not communicating properly
 
F708  0 7 0 8 
Version 
COM Version is not compatible with the ACM
 
F709  0 7 0 9 
 
Cold Water Cup Switch Input missing and 0x70 message 
is received from COM (ACM Only)
 
Dispense message is received and 30 
the Cup Switch input is still not 
 
F710  0 7 1 0 
Cold Water Cup Switch Input present and no 
dispense 
is received from COM (ACM Only) 
Cup Switch input is present for 30 seconds 
and no 
dispense message has been received 
F711  0 7 1 1 
Hot Water Cup Switch Input missing and 
dispense 
is received that requires the cup switch (ACM 
 
Dispense message is received and 30 
seconds later the Cup Switch input is still not 
present
 
F712  0 7 1 2 
Hot Water Cup Switch Input present and no 
dispense 
is received (ACM Only) 
Cup Switch input is present for 30 seconds 
and no 
dispense message has been received 
F713  0 7 1 3 
FF Door open for 15 minutes without closing
 
 
F714  0 7 1 4 
FF Door open for 60 min. in the last 24 hours
 
 
F715  0 7 1 5 
50 FF Door Openings in the last 24 hours.
 
 
F716  0 7 1 6 
FZ Door open for 15 minutes without closing
 
 
F717  0 7 1 7 
FZ Door open for 60 min. in the last 24 hrs.
 
 
F718  0 7 1 8 
50 FZ Door Openings in the last 24 hours.
 
 
ACM (Appliance Communication Module) Energy Management Accessory 
Interaction Fault Codes