Simon Security System 71
Sensor Group Characteristics
Type
Name/Application Siren Type
Delay
Restoral
Supervisory
Active
in
Levels
00 Fixed Panic: 24 hour audible fixed emergency button Intrusion I No Yes 1234
01 Portable Panic: 24 hour audible portable emergency buttons Intrusion I No No 1234
02 Fixed Panic: 24 hour silent fixed emergency buttons. Status light will not blink. Silent I No Yes 01234
03 Portable Panic: 24 hour silent portable emergency buttons. Status light will not
blink.
Silent I No No 01234
04 Fixed Auxiliary: 24 hour auxiliary sensor Emergency I No Yes 01234
05 Fixed Auxiliary: 24 hour emergency button. Siren shut off confirms CS report Emergency I No Yes 01234
06 Portable Auxiliary: 24 hour portable auxiliary alert button Emergency I No No 01234
07 Portable Auxiliary: 24 hour portable auxiliary button. Siren shut off confirms CS
report
Emergency I No No 01234
08 Special Intrusion: such as gun cabinets and wall safes. DTIM (tamper only) Intrusion I Yes Yes 1234
09 Special Intrusion: such as gun cabinets and wall safes. Intrusion S Yes Yes 1234
10 Entry/Exit Delay: Entry/Exit Delay that require a standard delay time. Chime Intrusion S Yes Yes 24
13 Instant perimeter: Exterior doors and windows. Chime. Intrusion I Yes Yes 24
14 Instant Interior: Interior doors Intrusion F Yes Yes 234
15 Instant Interior: Interior PIR motion sensors* Intrusion F No Yes 234
16 Instant Interior: Interior doors Intrusion F Yes Yes 34
17 Instant Interior: PIR motion sensors and Sound sensors* Intrusion F No Yes 34
18 Instant Interior Cross-Zone# PIR motion sensors* Intrusion F No Yes 34
19 Delayed Interior: interior doors that initiate a delay before going into alarm* Intrusion S Yes Yes 34
20 Delayed Interior: PIR motion sensors that initiate a delay before going into
alarm*
Intrusion S No Yes 34
21 Local Instant Interior: 24 hour local alarm zone protecting anything that opens
and closes. No Reports
Intrusion I Yes Yes 1234
22 Local delayed interior: same as group 21, plus activation initiates a delay
before going into alarm. No reports.*
Intrusion S Yes Yes 1234
23 Local instant Auxiliary: 24 hour local alarm zone protecting anything that opens
and closes.‡ No reports
Emergency I Yes Yes 01234
24 Local Instant Auxiliary: 24 hour local alarm zone protecting anything that opens
and closes. Sirens shut off at restoral. No reports.*
Emergency I Yes Yes 01234
25 Local Special Chime: Notify the user when a door is opened. Sounds emit from
a local annunciator.* Direct Bypass and Unbypass when no Special Motion
Chime sensors are in the security system. No reports
Three Beeps I No Yes 01234
26 Fire: 24 hour fire, rate-of-rise heat, and smoke sensors§. Fire I Yes Yes 01234
27 Lamp control or other customer feature.‡ No reports Silent I Yes Yes 01234
* This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
§ This type is required for UL-listed residential fire alarm applications.
This type has not been investigated by UL.
# See “Cross Zoning” section on page 72
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is not active, otherwise alarm sounds after programmed
entry delay time)