1997 REFRIGERATORS GLOBAL NEW GENERATION
SxS
© General Electric Company 1997 30
“system check/reset” and “crushed ice”
pads simultaneously. Then, observe:
One beep will be sounded then, for five
seconds, the “normal” indicator and all
other red and green indicators will be
illuminated and the display will show 8E.
After five seconds, the display will show
a flashing PF, the “normal”, crushed OBSERVE:
ice” and “door alarm” indicators will ONE BEEP,
remain illuminated. The “door open” ALL LED INDICATORS LIT 5 SECONDS,
indicator will remain illuminated if BE DISPLAYED, THEN
either door is open. The “warm FLASHING PF DISPLAYED
temperature” indicator will remain “NORMALLIT
illuminated if the freezer temperature is “CRUSHED ICE” LIT
above 13ºC (55ºF). The recess light will DOOR ALARM” LIT
not be illuminated. “DOOR OPEN” LIT & BEEPER BEEPS
- IF DOOR OPEN
“WARM TEMP” LIT
- IF TEMPERATURE ABOVE 55ºF